- This document describes the PID Controller Custom VBX Control.
-
-
- CONTENTS
-
- 1. Product Description
- 2. Legal Information
- 3. Installation
- 4. Usage
- 5. Support
-
-
- ----------------------------------------------------------------
-
- 1. Product Description
-
- The PID Controller VBX Control is a Microsoft Windows DLL designed and
- implemented in compliance with Microsoft standards for
- interfacing with Visual Basic.
-
-
-
- The control functions like a standard Proportional-Integral-Derivative
- controller used in industrial plants. It can be used for modeling
- chemical processing equipment and other kinds of plant installations that
- use closed-loop feedback control. See appendix A for a simple introduction
- to process control.
-
- To the application programmer, the interface to the slider is similar
- to the other MS Windows controls, with a few special messages added for
- performing operations specific to the PID control.
-
- Being a VBX control, the programmer can add the PID Control to the
- tool palette in Visual Basic. This allows use of the control in Visual
- Basic forms. Since Visual C++ supports use of VBX controls, the slider
- control can also be used in the Visual C++ environment.
-
- Use of the PID Controller in a finished VB or Visual C++ application
- requires the PID Control DLL (pid.vbx) to be installed with the application.
- This is true of all custom controls written for MS Windows.
-
- There are properties available that allow the programmer to control
- the behavior and appearance of the Control.
-
- All communication between the PID Control and the application is
- performed using the standard Windows message mechanism for controls.
- Design of the PID Control message mechanism allows the application to
- continuously monitor the settings of the control.
-
- -------------------------------------------------------------------
-
- 2. Legal Information
-
- The purchaser of the PID Control is allowed to use it and
- distribute it in applications without paying any royalty, and without
- printing or displaying a copyright notice for the control. This only
- includes distribution of the PID Control DLL (PID.VBX). It does
- not include distribution of documentation that comes with the
- Control.
-
- The purchaser of the PID Control may distribute the control DLL with
- applications that are networked (multiple users accessing the DLL from
- a file server) without paying any license fees to Northeast Data Corp.
-
-
- -------------------------------------------------------------------
-
- 3. Installation
-
- Create a "PID" directory on your hard disk and copy all files from
- the distribution disk to the directory. You should copy the pid.vbx
- file to your Windows\System directory.
-
- Start Visual Basic or the Visual C++ App Studio applications and use
- the custom control installation function to install the pid.vbx
- control.
-
-
- -------------------------------------------------------------------
-
- 4. Usage
-
-
- PROPERTIES
- ----------
-
- Action - Stop, Run, Reset. Reset causes all values stored in the
- controller to be reset to their controller startup
- settings.
-
- BackColor - Sets the background color.
-
- DragIcon - Name of the icon that will appear when the control is dragged.
-
- DragMode - Normal or automatic.
-
- Gain - The sensitivity of the controller. This value is multiplied
- times the difference between the setpoint and measured value,
- then divided by difference between the maximum and minimum
- control values (the range of the controller). The value is
- expressed as a percentage, so 100 will cause a 50% output
- when the difference between measured value and setpoint
- is 1 half of the span of the controller (100 degrees).
-
- Height - Height of control.
-
- Index - Index of control.
-
- Left - Left position.
-
- Measured - Position of the measured value arrow.
-
- Mode - Manual or Automatic. If set to automatic, the controller
- calculates and sets the output value based on the measured
- value and setpoint. If set to manual, the controller does
- not adjust the output, but allows you to set it manually.
- Setting the mode to manual also allows you to write your
- own algorithms for controlling the output based on the
- measured value and setpoint.
-
- MVColor - Color of the measured value arrow.
-
- MVTickColor - Color of the tick marks on the measured value scale.
-
- Name - Standard property for the name of the control.
-
- OPColor - Color of the output arrow.
-
- OPMode - Normal or Reverse. In reverse mode the output is set
- to 100% when the measured value is greater than the
- setpoint. In normal mode, the output is zero when the
- measured value is over the setpoint. This is useful for
- controlled devices that work in opposite fashions. For
- example, some pneumatic valves are closed at 100% output
- and wide open at 0% output. Other valves are the opposite
- of this.
-
- OPTickColor - Color of the tick marks on the output scale.
-
- Output - Position of the output arrow on the output scale. This
- can only be set if the Mode property is set to Manual.
-
- Poll - Controller update period (in seconds). This value should
- be set to something reasonable (a few seconds). Setting it
- too low will cause the control to take a large amount of CPU
- time.
-
- Preact - This value determines how many minutes the controller
- "looks ahead" to determine how the output should be adjusted.
- The calculation is done by extrapolating from the previous
- measured value to determine what the value will be at the
- specified lead time. This setting affects the ability of
- the controller to respond ahead of time to rapid changes in
- the measured value.
-
- Reset - The number of times per minute that the normal output
- calculated based on the Gain is reapplied to the output.
- This setting affects the ability of the controller to correct
- for a continuous offset between the setpoint and measured
- value.
-
- SetPoint - Current setpoint position. This must be a value between
- or including the current minimum and maximum values of
- the controller.
-
- SPColor - Color of the setpoint arrow.
-
- SPMax - Maximum control value. This must be greater than the
- minimum value. This established the maximum value for
- the setpoint and measured values.
-
- SPMin - Minimum control value. This must be less than the maximum
- value. This establishes the minimum value for the setpoint
- and measured values of the controller.
-
- SPTickColor - Color of the tick marks on the setpoint scale.
-
- TabIndex - Control tab order.
-
- TabStop - If this is turned on (1 instead of 0), the PID controller can
- be activated by tabbing to it with the TAB key.
-
- Tag - Control tag.
-
- Top - Top of control window.
-
- Visible - Visible/Invisible attribute.
-
- Width - Width of control.
-
-
- EVENTS
- ------
-
- These events work the same way as for other VBX controls.
-
- DblClick
- DragDrop
- DragOver
- GotFocus
- KeyDown
- KeyUp
- LostFocus
- Measured
- Output
- Setpoint
-
- In order to update values in your application based on the current
- position of the PID control, you should handle the Output and Setpoint
- events. The measured value event is not usually needed, since it is
- your application that sets the measured value based on the controller
- output. The setpoint event will occur when the user drags the setpoint
- arrow in the controller.
-
-
-
- -----------------------------------------------------------------------
-
- 5. Support
-
- You don't get any until you register.
-
-
-
- APPENDIX A - Process Control Overview
-
- There are many books available on process control theory. You can find
- them at any good technical library. Process control is a complex field
- of study - far too broad to cover in detail in this document. The
- following covers some of the basics to get you started. A lot can be
- learned just by "playing" with the PID VBX control. It is possible to
- connect your PC to laboratory equipment through a special analog adapter
- and perform real process control, using the PID control in Visual Basic
- or Visual C++ to perform the control calculations and output.
-
- Process control is divided into two broad categories; "Open Loop" and
- "Closed Loop". Open loop controllers send an output signal (air pressure
- or electrical) to a pneumatic valve or electronic solenoid. The level of
- the output signal is adjusted with no knowledge of conditions at the
- point of control. For example, a steam valve could be set to 50% of it's
- travel. The kettle of water being heated is at some unknown temperature
- and heats up as steam is fed to it. The temperature of the water rises
- continuously to some point of equilibrium. No change occurs to the steam
- valve setting unless the operator manually adjusts the output to the valve.
- This type of control is manual.
-
- Closed loop control is a technique for automatically adjusting valve or
- other component settings based on the measured value of the material being
- controlled. For example, placing a thermocouple in the kettle of water
- and feeding the measured temperature back to the controller allows the
- controller to determine a new setting for the steam valve.
-
- In closed loop control, the tricky part is coming up with an algorithm
- that determines the best setting for the valve or other device based on
- the measured input. It's tricky because of the large number of physical
- characteristics of the plant that affect the behavior of the measured
- feedback signal and the signal going out to the valve. Various things
- cause time delays in the sensing of input values and adjustment of
- output devices. Since there are usually more complex things to control
- than a kettle of water, the nature of the fluid or whatever is being
- controlled various widely. For example, typical chemical reactions
- cause enormous perturbations in the stability of the system (the extreme
- case being an explosion). Modern control theory attempts to quantify
- all these factors and produce optimum control algorithms.
-
-
- PROPORTIONAL CONTROL
- ====================
-
- The simplest form of closed-loop control is "Proportional". The output
- signal is determined by the difference between the setpoint and the
- measured value in relation to the range of the controller. A multiplier
- (called the "Gain") is used to determine the new output value. The output
- is calculated as:
-
- setpoint - measured value
- ------------------------- * (gain/100)
- max output - min output
-
- A gain of 100% means, for example, a setpoint of 75 degrees and a current
- water temperature of 50 degrees results in an output of 25% (where the
- output ranges from zero to 100% of the valve range). A gain of 2 would
- cause an output of 50%. This assumes the span of the controller (range
- of measured value and setpoint) is 100.
-
- This type of control is adequate for some systems. Industrial controls
- implement this type of control (as well as all those described in this
- document) by pneumatic elements using air pressure or by electrical
- components using electrical sensors and solenoids. The PID VBX control
- implements control by running a timer that periodically reads properties
- set by the application (the key one being the measured value). The
- timer period can be set using the "Poll" property.
-
-
- RESET CONTROL (Integral)
- =============
-
- Then things get a little trickier. What if 25% output is not enough to
- heat the water (or whatever) above 50 degrees? The controller is now at
- equilibrium; no further changes in water temperature will occur. The system
- operates at a steady offset between the setpoint and the measured value.
- Usually, this is not quite what is desired. The operator can correct the
- condition by manually setting the setpoint to 100 degrees, hoping that the
- controller will settle down with an offset of 25 degrees, leaving the
- water temperature at the desired 75 degrees. Depending on the system
- behavior, this may not happen. The operator may have to "play" with
- the setpoint to find the setting that works.
-
- The next type of control operation attempts to correct this problem. It
- does, in effect, what the operator would have to do manually. That is,
- it resets the effective setpoint when it sees that the measured value
- does not come up to the setpoint over some period of time. This element
- of control operation is called, appropriately "Automatic Reset", or just
- "Reset". The numeric value for the reset is the number of times per
- minute that the controller adds the output calculated from the simple
- gain to the current output value. The output is adjusted rather than
- the setpoint - the effect is the same, and is preferable to putting the
- setpoint to a location that looks strange to the operator.
-
- The effect of reset is to, over time, eliminate the offset between the
- setpoint and the measured value. The disadvantage to this technique is
- that reset tends to desensify the controller. That is, once the setpoint
- has been reached, the reset may have driven the output so high that the
- measured value "overshoots" the setpoint. Also, if the controller is
- left in operation (doing calculations) while active components of the
- system are turned off, the reset component will build up a large output
- value. When the components are turned on, the controller massively
- overshoots the setpoint. For example, if a manual steam valve is turned
- off while the controller is running, reset will eventually drive the
- output to 100% because the measured value never comes up to the setpoint
- (no steam available). When the manual valve is opened, the reset component
- takes no effect until the measured value has reached the setpoint. By
- the time the controller has determined there is no continuing offset, the
- measured value has overshot the setpoint by a large value. This
- phenomenon is sometimes called "Reset Windup".
-
- This problem can be overcome to some extent by providing a switch to
- turn the controller on and off. While the system is not being used, the
- controller is turned off. These prevents the reset component from building
- up incorrect output values. The VBX control contains an Action property for
- turning the controller on and off and for resetting it, which zeroes out
- all retained calculations.
-
- Reset control action is also known as "Integral" control, since controller
- output is determined by integrating offsets over a period of time.
-
-
- DERIVATIVE CONTROL (Preact)
- ==================
-
- Many systems have lengthy delays between the sensing of temperatures or other
- parameters and transmission of these to the controller. There can also be
- extensive delays in the transmission and use of output signals from the
- controller. The effect of these problems is that the new adjustment at the
- point of control is incorrect by the time it arrives. This problem is
- evident in all controls by observing a phenomenon known as "Cycling", where
- the measured value repeatedly overshoots and undershoots the setpoint. A
- controller operating in this condition is said to be "hunting".
-
- There are also process events that "surprise" the controller. A chemical
- reaction typically produces these at the time the chemicals begin to
- react. Sensitive proportional control can somewhat compensate for this
- problem, but Reset control tends to make things worse if the reaction
- occurs when the measured value is below the setpoint, since Reset will
- continue to boost the output until the measured value is above the setpoint.
-
- Derivative control looks at the difference between the previous measured
- value and the current one. It calculates a counter-output to be applied
- to the proportional output. In effect, it guesses what the next measured
- value will be based on the slope (hence the term "Derivative") of the
- measured value and generates an output to "get ahead" of the process.
-
- Derivative control is also known as "Preact". The numeric value for the
- preact is the number of minutes to look ahead to calculate the output. For
- example:
-
- If the previous measured value was 45 degrees and occured 10 seconds ago
-
- If the current measured value was 50 degrees and the Preact value is .5
-
- The rate of change in measured value is 30 degrees per minute.
- The preact value indicates we should use the measured value .5 minutes
- in the future. Based on the rate of change, the measured value will be
- 65 degrees in .5 minutes ( 50 (current value) + 30 (deg/min ) / .5 (min) ).
-
- The preact component will calculate an output based on 65 degrees,
- whereas the proportional component will base its calculation on 50 degrees.
-
- The outputs calculated by proportional, integral, and derivative components
- are added together to form the new output value.
-
-
- TUNING
- ======
-
- The business of setting optimum values for Gain, Reset, and Preact is
- known as "Tuning" the controller. This is typically done through trial
- and error. Although there are many algorithms used for calculating these
- settings, many process systems are so complex that the trial-and-error
- technique is the most effective.
-
- Controllers can become more complex by "cascading" them. In this
- configuration, the output from one controller is used to set the setpoint
- of another controller. Two controllers cascaded is the norm, but there is
- no technical limit. Tuning these types of controllers is usually done by
- tuning the controller closest to the process (called the "slave") first,
- and tuning the "master".
-
-
-
- APPENDIX B - Example Visual Basic Application
- ==========
-
- The application provided with the PID control is a simple example of
- controlling a kettle of water (or whatever). The application sets the
- measured value based on the output of the control and the current
- temperature of the water.
-
- Edit boxes let you play with the Gain, Reset, and Preact. Buttons let
- you stop, start, and reset the controller.
-
- Three graph controls are used to chart the setpoint, measured value, and
- output.
-
- The game here is to try your hand at tuning the controller. You can test
- your skill by making controller settings and adjustments to the setpoint.
- The goal is to tune the controller for optimum measured value control.
- You need to minimize cycling, offsets, and overshoots.
-
- You can change the behavior of the system by modifying the algorithms
- for calculation of the measured value. You may want to add an "Explosion"
- button or something like that to give a sudden burst in measured value
- to see how your controller responds.
-
- If you have better ideas for controlling a process, set the mode of the
- controller to "Manual" and write your own subroutine for calculating the
- output based on the measured value and setpoint. This, in effect, lets
- you design your own industrial controller. You can add all kinds of
- logic for dealing with special behavior of your process. For example,
- you may know that your chemical reaction "takes off" at exactly 14
- minutes after the temperature reaches a setpoint of 67 degrees. Your
- algorithm could make adjustments to setpoint, set the controller and
- let your algorithm "take over", or make adjustments to the gain, reset,
- and preact. This is pretty cool, since many industrial controllers
- don't have nearly this much flexibility.
-
- It's also fun to hook up the MCI control and play wave files for special
- effects when certain things happen in the controlled process.
-
-
- Enjoy.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-